Home Print this page Email this page Users Online: 1412
Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2019  |  Volume : 7  |  Issue : 3  |  Page : 151-155

Effect of sterilization on cyclic fatigue resistance of Proflexendo endodontic rotary files


Department of Restorative Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia

Correspondence Address:
Prof. Emad O Alshwaimi
Department of Restorative Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P. O. Box 1982, Dammam 31441
Saudi Arabia
Login to access the Email id

DOI: 10.4103/sjmms.sjmms_123_17

PMID: 31543735

Rights and Permissions

Background: Proflexendo file (Nexen, Houston, TX, USA) is a recently developed, novel nickel-titanium rotary file. However, several physical properties of the Proflexendo system remain to be investigated. Objectives: The aim of this study was to determine the effect of sterilization on cyclic resistance of Proflexendo files. Material and Methods: A total of 120 unused Proflexendo rotary files (40 each of file sizes 40/0.04, 30/0.04 and 20/0.06) were used in this study. Each set of files was subdivided into four groups of ten files. Group 1 did not undergo any sterilization (control), Group 2 underwent two rounds (2×) of sterilization, Group 3 five rounds (5×) and Group 4 ten rounds (10×). Cyclic fatigue resistance was tested using an artificial canal with a 5-mm radius curve. Results: The nonsterilized size 30/0.04 files had the highest cycles to failure, followed by the nonsterilized size 40/0.04 and 20/0.06 files (P < 0.001). With increasing rounds of sterilization, cycles to failure reduced for sizes 40 (2×, 5× and 10×) and 30 (2×) files compared with nonsterilized sizes 40 (P < 0.05) and 30 files (P < 0.001), respectively. Conclusion: Under the conditions of the current study, the results provide preliminary evidence that autoclave sterilization of Proflexendo rotary files reduced their cyclic fatigue resistance, except for size 20 (2× and 5×) and 30 (10×) files, in which resistance increased. Single use of this file is recommended to reduce the risk of separation.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed1194    
    Printed111    
    Emailed0    
    PDF Downloaded206    
    Comments [Add]    

Recommend this journal